GENERATOR SELECTION

How to Choose the Right Diesel Generator Capacity in kVA

A practical guide to generator sizing: connected load, starting current, power factor, duty rating and site conditions.

Choosing generator capacity requires more than adding the wattage printed on equipment. Motors, pumps, compressors, lifts and other inductive loads may draw higher current during startup. A qualified electrical professional should assess the complete load profile and verify the final generator rating.

Prepare a connected-load list

List every item expected to operate from the generator. Record rated power, voltage, phase, running current and whether the equipment operates continuously or intermittently. Identify essential loads separately from loads that can be switched off during an outage.

Account for motor starting current

Motors can require a higher current during startup than during normal operation. The starting method, motor size, load condition and number of motors starting together affect generator selection. Staggering starts or using suitable starting equipment may change the required capacity.

Understand kW, kVA and power factor

kW represents real power, while kVA represents apparent power. The relationship depends on power factor. Equipment mix and power quality requirements matter, so a simple kW-to-kVA conversion should be treated as an initial estimate only, not a final engineering selection.

Consider operating conditions and reserve

Consider ambient temperature, altitude, ventilation, installation arrangement, future load growth and the generator duty rating. Avoid oversizing or undersizing without analysis. The correct reserve margin depends on the actual application and load characteristics.

Confirm the selection before ordering

Provide the load schedule, site location, operating hours, required voltage and phase, and details of large motors to the supplier or electrical consultant. Ask for the proposed generator rating and technical basis in writing.

Can I select a generator based only on total watts?

No. Motor starting current, power factor, load steps, duty rating and site conditions must also be evaluated.

What does kVA mean on a generator?

kVA is apparent power and is commonly used to state generator capacity. The usable real power in kW depends on power factor.

Should I choose a larger generator for safety?

Not automatically. Oversizing and undersizing both have technical and operational implications. Have the load profile assessed.